<LOGO>
FM Transmitter Measurement Report
Created: 2026-10-06 17-04-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 47 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 2.7 kHz -46 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 65 kHz 17245 0,0174
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,5 dBr 2,26 dBr 4,2 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Ronald Brautigam (piano) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 65 kHz MIN: 11 kHz % above 76 kHz: 0,0174 Acquired: 2026.10.06 17.03.13 Total samples: 17245 Equivalent time: 0:14:22 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 4,2 dBr MIN: -1,5 dBr AVE: 2,26 dBr % above 12,2 dBr: 0,0 Last value: 3,9 dBr (2026.10.06 17.03.12) 16.50 16.52 16.54 16.56 16.58 17.00 17.02 -2 0 2 4 Pm [dBr]